Skip to main content
ExLibris
  • Subscribe by RSS
  • Ex Libris Knowledge Center

    Memory corruption detected

     

    • Product: Aleph
    • Product Version: 20
    • Relevant for Installation Type: Dedicated-Direct, Direct, Local, Total Care

     

    Problem Symptoms:
    The following message is received during load: 
    Execution error : file '' 
    error code: 252, pc=0, call=1, seg=0 
    252 Memory corruption detected (addr=0xae9a004, type=1/1)


    Cause:
    Program overflow caused by large data

    Resolution:
    Correct the data (in this case it was large field 505, which had to be split in several sub-fields).

     

     


    • Article last edited: 15-May-2016
    • Was this article helpful?