    Problem Symptoms:
    Running a p_print_03 with a fix containing a large number of replace-string statements I seem to be hitting a limit...
    500 or more replace-string's results in an empty output and a error message in the logfile
    Execution error : file '/exlibris/aleph/a20_1/aleph/exe/fix_doc_script.gnt'
    error code: 114, pc=0, call=1, seg=0
    114 Attempt to access item beyond bounds of memory (Signal 11)

    Remaining below 500 there's no problem

    Cause:
    This is a limitation in the program.

    Resolution:
    This problem is solved in Aleph 21 with rep_change #000073.