sys-01: "Invalid server type. Must be ..."
- Article Type: General
- Product: Aleph
- Product Version: 20
Problem Symptoms:
When sys-01 ("Restart Server") is run from the job_list, the job log shows:
setenv p_server "www"
and then:
F01: Invalid server type. Must be "PC", "WWW" or "OCLC"
Cause:
Lowercase value for server type in ./alephe/pc_b_eng/p-sys-01.xml.
Resolution:
Change the value line in ./alephe/pc_b_eng/p-sys-01.xml from: "<value>www</value>" to: "<value>WWW</value>" .
Additional Information
If the error occurs even with "WWW", try submitting the job from the command line:
csh -f $aleph_proc/p_sys_01 VIR01,WWW > & $alephe_scratch/vir01_p_sys_01.log &
If the above works OK, replace the existing sys-01 entry in the job_list with the following:
W0 hh:mm:ss N csh -f /exlibris/aleph/a2n_n/aleph/proc/p_sys_01 VIR01,WWW
And then restart the job daemon (util e/15/1).
Category: System Management (500)
- Article last edited: 6/18/2014