    Symptoms

    * Enter large number in "Jump ahead" box in Preview and click Jump; results in run-time errors:
    Run-time error '65099': Connection lost. Application will be aborted.
    Run-time error '440': Application-defined or object-defined error

    Defect Status

    Issue VYG-6240 is resolved for Voyager 9.1.1 and higher.

    Replication Steps

    1. Find or create a large record set in GDC (100,000 records or more)
    2. Preview > Choose record set & any data change rule set group
    3. In Preview window, enter 50000 in "Jump ahead:" box
    4. Click Jump button
    5. Within a few seconds, client gives error: Run-time error '65099': Connection lost. Application will be aborted.
    6. Click OK and client gives second error: Run-time error '440': Application-defined or object-defined error
    7. Click OK and client closes.

    Workaround

    Enter smaller number (i.e., 25000) in "Jump ahead:" box

    Additional Information

    Number in "Jump ahead:" box that produces error may vary by version.