Skip to main content
ExLibris
  • Subscribe by RSS
  • Ex Libris Knowledge Center

    System generated values in MARC control fields appear to be updateable in GDC

    • Product: Voyager
    • Product Version: 9.2.1
    • Relevant for Installation Type: Multi-Tenant Direct, Dedicated-Direct, Local, Total Care

    Symptoms

    GDC 'after' record shows change made to system-generated value in control field

    After running Data Change Job to update database, record in Voyager does not reflect updated value in 'after' record

    Defect Status

    Issue VYG-7162 is currently in Development.

    Replication Steps

    1. Create a data change rule set that updates a system generated value, i.e., 008/00-05 (see attached)
    2. Add the rule set to a rule set group
    3. Execute a data change job with this rule set group
    4. Review the after record. Note that it contains the updated value.
    5. Review the record in the database. Note that it was updated by the process, but the updated value is not present.

    Workaround

    None. The final result is intended functionality. The functionality in Global Data Change / changed 'after' record is misleading.

     


    • Article last edited: 02-Feb-2017