    1. Introduction
    2. Event Timeline
    3. Root Cause Analysis
    4. Customer Communication

    Introduction

    This document serves as a Root Cause Analysis for the campusM EU01 service interruption experienced by Ex Libris customers.


    The goal of this document is to share our findings regarding the event, specify the root cause analysis, outline actions to be taken to solve the downtime event, as well as preventive measures Ex Libris is taking to avoid similar cases in future.

    Event Timeline

    Service interruption was experienced by Ex Libris customers served by the campusM EU01 instance at the Amsterdam Data Center during the following times: 

    August 3, 2025 from 03:50 AM until 05:35 AM Amsterdam time.

    During the event, Service was unavailable for the environment.

    Root Cause Analysis

    Ex Libris Engineers investigated this event to determine the root cause analysis with the following results:

    As part of our continuous efforts to ensure the availability, stability, and security of our Private Cloud services, we recently performed an upgrade to our load network infrastructure. During this process, a temporary misconfiguration occurred due to a software bug, resulting in a network disruption. 

    Upon identification, our network engineering team promptly implemented a mitigation strategy provided by our vendor to manually correct the misconfiguration. Normal service has been restored. 

    Technical Action Items and Preventive Measures 

    Ex Libris has taken the following action and preventive measures to avoid such an occurrence in future:

    • The Network team Implemented a temporary protocol adjustments prior to system upgrades to avoid potential known bugs.

    Customer Communication

    ExLibris is committed to providing customers with prompt and ongoing updates during Cloud events. Ongoing and prompt updates on service interruptions appear in the system status portal at this address: http://status.exlibrisgroup.com/

    These updates are automatically sent as emails to registered customers.

     

    View article in the Exlibris Knowledge Center
    1. Back to top
      • campusM EU01 - RCA - September 22, 2025
      • campusM EU01 Performance Issues - RCA - September 30 - October 15, 2024
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Community Content Type
      Training Materials
      Content Type
      Product Materials
      Language
      English
      Product
      Alma Specto
    2. Tags
      1. contype:prdctmt
      2. Root Cause Analysis
    1. © Copyright 2026 Ex Libris Knowledge Center
    2. Powered by NiCE Knowledge Management ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved