Skip to main content
ExLibris
  • Subscribe by RSS
  • Ex Libris Knowledge Center

    Primo Uptime Report for Primo TC APAC02 Instance (APAC) - Q2 2016

    Primo Uptime Quarterly Reports are published each quarter to provide a comprehensive view of our uptime performance as measured over the last three (3) months and over the last twelve (12) months. The report measures our performance as defined in the Service Level Agreement.

     

    This document details the uptime report for the Primo TC APAC02 in APAC.

     

    The Primo uptime measured on a rolling 12 month basis July 2015 - June 2016 is 99.90%

    The Primo uptime measured on a rolling 3 month basis April 2016 - June 2016 is 99.71%

     

     

    Please note our System Uptime Status page, which allows our customers to view the current status of their instance/environment at any time, using the following link: http://status.exlibrisgroup.com

     

     

    Unscheduled downtime incidents in Q2 2016

    Date

    Start time

     (SGT)

    End time

    (SGT)

    Duration
    (minutes)

    Description

    April 03, 2016 09:40 AM 11:40 AM 120

    Ex Libris engineers found that the issue was caused by a high amount of packet loss on the Firewall. The issue was triggered after a firmware upgrade of the firewall and the packet loss had been identified as a mismatch between a configuration and the license on the firewall. The issue was resolved by removal of

    the problematic configuration.

    April 03, 2016 02:20 PM 04:40 PM 140
    April 20, 2016 11:43 AM 12:08 PM 24 Some of the queries in the environment had taken longer than expected to complete. This issue had caused the system to build a high queue that prevented it from operating at all. The search engines were immediately restarted, this action has restored normal service.
    June 17, 2016 07:42 AM 08:59 AM 77 There has been communication disturbance identified with the database host to the network. This communication disturbance was related to a defect in the firmware version.
    June 21, 2016 04:20 PM 04:36 PM 16

    Scheduled downtimes during maintenance windows in Q2 2016

    Start Date

    Start Time

    (SGT)

    End Time

    (SGT)

    Duration (Minutes)

           

     

    Total unscheduled downtime minutes during past 12 months

    Quarter

    Total unscheduled downtime in Quarter (minutes)

    Q3 2015 50
    Q4 2015 119

    Q1 2016

    0

    Q2 2016

    377

     

    How is Primo Uptime Calculated?

    The uptime calculation is based on the following calculation (as defined in the Alma Service Level Agreement):

    "Uptime" means the total period in minutes during which the Service is available for access and use during this period.

     

    Uptime Percentage” means Uptime expressed as a percentage, calculated in accordance with the following formula:   

      

     Uptime Percentage = X /(Y–Z) × 100    

    Where: 

      X = Uptime

      Y = Last 12 months period

      Z = The duration (in minutes) of any SLA Exclusions* during these 12 months

     

    *SLA exclusions are defined in the contract SLA (e.g. Scheduled maintenance, etc.)

     

    Further Information

    If you have any queries on the information within this report please contact Ex Libris through your usual channel.