Can't connect to items in GUI; "Cannot run program"; GUI Version: <blank>
- Article Type: General
- Product: Aleph
- Product Version: 21
Problem Symptoms:
*Cataloging shuts down when trying to move from a bib or HOLD record to items.
*Circulation error messages when trying to 'Push to Items":
"Cannot run program C:\AL500v21\catalog\bin\catalog.exe"
"Items application currently not running."
*In Cataloging, clicking on Help --> About at the top, shows GUI Version: <blank>
Cause:
.\catalog\bin\catalog.exe file different from other staff PCs
Resolution:
1. Save .\catalog\bin\catalog.exe file as catalog.exe.save
2. Open the Circulation module and click on 'ALEPH' in upper left, then 'Version Check'
3. Click on 'Update All'.
Category: Cataloging (500)
Subject: Items (500)
- Article last edited: 10/8/2013