    Description:
    We have installed Aleph 20.2 and are upgrading from Aleph 18 to 20.
    After we have executed step 1017 in UEX kit 18-19 (version 1.30) we see that our tab100 in ABC01 ist corrupted.
    It only has one line:
    ISSN-CODE=ISN

    What has happened?

    Resolution:
    Because of a PERL-module that was updated during installation of Aleph 20.2 (=Minor Release 2) some steps in UEX kits 18-19 and 19-20 may corrupt configuration tables. In UEX kit 18-19 the steps 1017, 51, 52, 53, 54, 55, 56, 57 and 60 are affected by this problem. In UEX Kit 19-20 the steps 21, 23 and 26 are affected.

    The problem has been fixed in UEX kit 18-19 version 1.31 and in UEX 19-20 kit version 1.13. We strongly recommend downloading the latest versions of these UEX kits if you have installed Aleph 20.2.