    Problem Symptoms:
    * New library environment created with libraries xxx01 and xxx50
    * When connecting to the library the following error message is displayed
    "c0180 6 and no access to library"
    * The library is not locked (See util c/4 Library lock status)
    * When clicking 'ok', the work can be continued

    Cause:
    The file ./xxx50/tab/path_convert refers to files that are redirected to a different place

    Resolution:
    * Change file ./xxx50/tab/path_convert to point to the correct file (see additional information for detailed instructions)
    * Restart the relevant servers (e.g. PC Server with util w/3/3)

    Additional Information

    Example for file rep_col.lng in $abc50/tab/path_convert

    $abc50_dev/abc50/tab/rep_col $abc01_dev/abc01/tab/rep_col

    Directory $abc01_dev/abc01/tab is redirected in $abc01/tab/path_convert to xyz01

    $abc01_dev/abc01/tab $xyz01_dev/xyz01/tab

    This type of re-direction chain is not allowed
    Refer to $xyz01_dev/xyz01/tab in abc50 directly

    1) Change line in ./abc50/tab/path_convert
    From
    $abc50_dev/abc50/tab/rep_col $abc01_dev/abc01/tab/rep_col
    To
    $abc50_dev/abc50/tab/rep_col $xyz01_dev/xyz01/tab/rep_col

    2) Restart the relevant servers (e.g. PC Server with util w/3/3)

    Category: System Management (500)