    Problem Symptoms:
    The process "Update Tables Package" (sys-03) is not ending

    Cause:
    Template names containing blanks

    Resolution:
    1. Rename the files having a blank in the name
    2. Rerun service "Update Tables Package" (sys-03)

    Additional Information

    Analysis:

    1. the process was started correctly, trying to create a new pc_cat.pck.new file in ./xxx01/pc_tab/catalog

    -rw-r--r-- 1 aleph exlibris 96552 Mar 28 14:36 pc_cat.pck.new

    2. The last file that was successfully included was:

    vi ./xxx01/pc_tab/catalog/pc_cat.pck.new
    PKC_FILE_BEGIN AF-Candidatura.MRC

    3. There are other templates, having a blank in the name:
    -rw-r--r-- 1 aleph exlibris 657 Dec 6 09:57 AF-Programa Nacional.MRC
    -rw-r--r-- 1 aleph exlibris 657 Dec 6 09:57 AF-Programa Europeu.MRC
    -rw-r--r-- 1 aleph exlibris 635 Dec 6 09:57 AF-Portugal 2020.MRC
    -rw-r--r-- 1 aleph exlibris 645 Dec 6 09:57 AF-Instrumento Financeiro.MRC
    -rw-r--r-- 1 aleph exlibris 651 Dec 6 09:58 AF-Fundo nacional.MRC
    -rw-r--r-- 1 aleph exlibris 650 Dec 6 10:31 AF-Fundo europeu.MRC