    Description:
    We just realized that new and modified records are not being indexed since Oracle was upgraded on our production server on March 11. The latest run_e_01 log in /tcu01/scratch ends with the following error lines:

    Oracle error: update_cursor1 z07
    ORA-03113: end-of-file on communication channel

    Oracle error: update_cursor1 z07
    ORA-03114: not connected to ORACLE

    * No ORACLE connection - process is terminated... *
    What should be done

    Resolution:
    When aleph_startup tried to start the ue_01, Oracle was not available and the procedure stopped.

    Do util e/1 to start ue_01 and it is processing the Z07s successfully.

    Additional Information

    ue_01, ORA-03114 error


    • Article last edited: 10/8/2013
    View article in the Exlibris Knowledge Center
    1. Back to top
      • UE steps
      • UE-01 shut down unexpectedly
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Language
      English
      Product
      Aleph
    2. Tags
      1. 16.02
      2. contype:kba
      3. Prod:Aleph
      4. Type:General
    1. © Copyright 2025 Ex Libris Knowledge Center
    2. Powered by CXone Expert ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved