    Description:
    After upgrading to version 18, we see the following errors in the pc_server log:

    Oracle error: io_z104_get_last_sequence
    ORA-00942: table or view does not exist

    Oracle error: io_z104_write
    ORA-00942: table or view does not exist

    Resolution:
    The reason for this error was the lack of a z104 table in ABC60.

    This table stores various triggers set up for cataloguing records by your staff. You should ask your cataloguers if they are using this functionality in abc60.

    If they are, then you should check if the z104 was defined for abc60 in the earlier version and include those records in the Upgrade Express.

    If they are not, you can just create this table in the new version using util a/17/1.