Problem Symptoms:
* When searching for a title in the OPAC (e.g. "American Economic Review") the inactive sfx icon is shown although the fulltext should be available.
Example of configuration
* $alephe_root/www_server.conf
setenv sfx_base_url http://demo.exlibrisgroup.com:9003/demo
* ./xxx01/tab/tab_sfx
! 1 2 3 4 5
!!!!!!!!!!!!!!!!!!!!-!!!!!!!!!!!!!!!!!!!!-!!-!-!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!>
XXX01 www_f_sfx 11 N getFullTxt
Cause:
The sfx_openurl_version is set to ver-0.1
Resolution:
1) Change variable setenv sfx_openurl_version in $alephe_root/aleph_start.private
old:
setenv sfx_openurl_version ver-0.1
new:
setenv sfx_openurl_version ver-1.0
2) Restart the web server (util w/3/1)
Category: Web OPAC (500)