ue_21 and p_publish_04 keeps crashing since Service pack 22.1
- Product: Aleph
- Product Version: 22
- Relevant for Installation Type: Dedicated-Direct, Direct, Local, Total Care
Problem Symptoms:
Background service ue_21 (Update Publishing Data) and p_publish_04 (Initial Publishing Process) keeps crashing with error:
Execution error : file '/exlibris/aleph/a22_2/aleph/exe/expand_doc_bib_avail.gnt'
error code: 114, pc=0, call=1, seg=0
Attempt to access item beyond bounds of memory (Signal 11)
Cause:
Defect
Resolution:
Install rep_change 002153.
This change is included in Service Pack 22.1.1.
Description: The publishing daemon job ue_21 fails after a while in some cases.
This happens when ue_21 is run using the expand program expand_doc_bib_avail without setting the parameter COLLECTION=Y.
- Article last edited: 15-May-2016