Self Check not working: "Circulation system operation failure"
- Article Type: General
- Product: Aleph
- Product Version: 19.01
Description:
I'm trying to test one of our self check machines with v19 but I can't get it to connect.
I get the following error from the self check machine:
Circulation system operation failure - Unable to send a ILS request - check connection and SIP configuration - ERR_SIP_WAIT_FOR_THREAD_START
And in the self check log (5332) there is only one line:
Fri May 16 15:18:06 EDT 2008 *** start sip2_server ***
It looks to me like everything is set up correctly so I haven't been able to find the problem.
Resolution:
[From site:]
I found out that our local network ipf.conf changes did not get reloaded properly. This has been fixed and I have tested the self check with v19 and it is working fine.
- Article last edited: 10/8/2013