    Description:
    Last weekend I ran the sequence of browse indexing jobs on Test. I had toggled off the UE processes with util w/5 during indexing. It all seemed to go well, but now, after indexing, the UEs won't start. They shut down immediately; we see the following message in the log:

    SYSTEM DOWN:EXITING - 05:10:13

    The util w/5 display looks like this:

    Global System Status

    Process Name Status
    ----------------------------- -----------------------------
    1. SYSTEM UP
    2. WWW-SERVER UP
    3. ACQ UP
    4. CIRC UP
    5. CAT UP
    6. ILL UP
    7. JOBD UP
    8. QUEUE-BATCH UP
    9. ALL-UE UP
    10. UE-01 UP
    11. UE-03 UP
    12. UE-06 UP
    13. UE-08 UP
    14. UE-11 UP
    15. UE-13 UP
    Enter L to View Library System status, T to Toggle [Exit]:

    so it *seems* that everything is UP.

    Resolution:
    Despite the preceding, when I typed "L" in util w/5, I saw this:

    ABC01 System Status

    Process Name Status
    ----------------------------- -----------------------------
    1. QUEUE-BATCH UP
    2. ALL-UE DOWN
    3. UE-01 UP (DOWN due to ALL-UE status)
    4. UE-03 UP (DOWN due to ALL-UE status)
    5. UE-06 UP (DOWN due to ALL-UE status)
    6. UE-08 UP (DOWN due to ALL-UE status)
    7. UE-11 UP (DOWN due to ALL-UE status)
    8. UE-13 UP (DOWN due to ALL-UE status)
    Enter T to Toggle [Exit]:


    So I did this:

    Enter T to Toggle [Exit]: T
    Enter sequence number to toggle, or return to exit: 2


    Which resulted in this:

    ABC01 System Status

    Process Name Status
    ----------------------------- -----------------------------
    1. QUEUE-BATCH UP
    2. ALL-UE UP
    3. UE-01 UP
    4. UE-03 UP
    5. UE-06 UP
    6. UE-08 UP
    7. UE-11 UP
    8. UE-13 UP


    I was then able to successfully start the abc01 ue_01 and ue_08.


    • Article last edited: 10/8/2013
    View article in the Exlibris Knowledge Center
    1. Back to top
      • UE: install customer data: unique constraint (ABC01.Z00_ID) violated
      • ue01 stalls with: "Execution error : file '.../fix_doc_ref_1.gnt'
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Language
      English
      Product
      Aleph
    2. Tags
      1. 18.01
      2. contype:kba
      3. Prod:Aleph
      4. Type:General
    1. © Copyright 2025 Ex Libris Knowledge Center
    2. Powered by CXone Expert ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved