    Upgrade Express util_upgrade Check Environment: "No alephe prof_library file"

    1. Last updated
    2. Save as PDF
    3. Share
      1. Share
      2. Tweet
      3. Share
    No headers
    • Article Type: General
    • Product: Aleph
    • Product Version: 18.01

    Description:
    Our Upgrade Express util_upgrade "Check Environment" function shows the following:

    Checking abc01...
    Checking abc10...
    Checking abc11...
    Checking abc50...
    Checking abc60...
    Checking pwd50...
    Checking alephe...
    Checking usm01...
    Checking usm10...
    Checking usm50...
    Checking usm60...
    Checking vir01...
    No alephe prof_library file

    Should there be a prof_library file under alephe?

    Resolution:
    When they do util_upgrade, "View/Update upgrade parameters" and select "1. View Current Parameters", it shows alephe in the "Libraries to be upgraded".

    It should not. There are no Oracle tables for alephe, so nothing to import. As far as aleph/u-tree files the Install customer data does the alephe separately and automatically. They should do "Update parameters" and remove "alephe".

    The "Checking usmnn..." lines indicate that they are trying to upgrade the USMnn libraries.

    In generating the "View/Update upgrade parameters" / "View Current Parameters" display, the ./util/make_default_conf procedure does the following:

    set libraries=`$uk_root/source/proc/non_demo_libs`

    that is, it specifically excludes the (USMnn) demo libraries.

    It's possible that this could be circumvented, but the USMnn demo libraries are *not* intended to be changed by the customer (except the conducting of temporary tests by them or by Ex Libris staff).

    The customer needs to use the USMnn tables as we are distributing them. They should *not* be carrying over USMnn data from a previous version.


    • Article last edited: 10/8/2013
    View article in the Exlibris Knowledge Center
    1. Back to top
      • Upgrade Express tries to upgrade USR00 library rather than actual $usr_library
      • Upgrade Express Utility ... Can only be run in a20_1 ... you cannot continue
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Language
      English
      Product
      Aleph
    2. Tags
      1. 18.01
      2. contype:kba
      3. Prod:Aleph
      4. Type:General
    1. © Copyright 2025 Ex Libris Knowledge Center
    2. Powered by CXone Expert ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved