Z13U-USER-DEFINED-X values does not appear in the customer reports
- Article Type: General
- Product: Aleph
- Product Version: 20
Problem Symptoms:
customer run reports via different services in the GUI which contains Z13U-USER-DEFINED-X parameters.
The values of those parameters does not appear in the reports
Cause:
fields Z13-USER-DEFINED instead of Z13U-USER-DEFINED
Resolution:
Changing the parameters in the forms which exist under
vi ../xxx01/form_lng
from
Z13-USER-DEFINED-X
to
Z13U-USER-DEFINED-X
Category: Acquisitions (500)