p_manage_01 keeps abc01 locked
- Article Type: General
- Product: Aleph
- Product Version: 18.01
Description:
When I run p-manage-01 in our Aleph Test environment it locks ABC01, and does not unlock it when the job is completed. None of the other indexing jobs do this (manage-02, manage-05, or manage-17) – they all unlock the library successfully when they are completed. This prevents me from being able to queue up our indexing jobs.
Resolution:
I find that the Mar. 24 ue_01's (run_e_01.22059 and run_e_01.27383) both stopped with the following error:
HANDLING DOC NO. - ABC01.000121333 11:08:44
Update z98 from z980 : 021000000001
Execution error : file '/exlibris/aleph/a18_1/aleph/exe/compress_data_ads.gnt'
error code: 114, pc=0, call=1, seg=0
114 Attempt to access item beyond bounds of memory (Signal 11)
This is not the same error you were seeing in previous ue_01 problems.
The compress_data_ads.gnt problem is discussed in KB 16384-2113. As noted in the last sentence, running p_manage_01 should correct the problem.
p_manage_01 stops the ue processes. When it is done (which it should be in a few hours), it will restart ue_01 and you should *not* see this problem processing the bib 000121333. If you do, let me know and I will analyze further.
- Article last edited: 10/8/2013