    "System is overloaded, try again" for OPAC searches (due to clock change)

    1. Last updated
    2. Save as PDF
    3. Share
      1. Share
      2. Tweet
      3. Share
    1. Description
    2. Resolution
    3. Additional Information
    • Article Type: General
    • Product: Aleph
    • Product Version: 20,21,22,23

    Description

    * The message "System is overloaded, try again" occurs for OPAC searches.
    * "Error: License limit exceeded" is seen in the www_server log.

    Cause:
    As part of a reboot the server clock was incorrectly set forward 4 hours. After the server had been up for 8 hours, the clock was corrected (set back 4 hours). This caused z63 (OPAC session) records which had been inactive to be re-activated, causing the number of Active users (as seen in util y/11/2) to exceed the number of Licensed users.
     

    Resolution


    Avoid changing the server time as part of a reboot.
    If the server time is inadvertently changed:

    • run Aleph shutdown 

    csh -f $alephe_root/aleph_shutdown

    • correct the time
    • run clear_vir01 (util x/8) cold 

    * run Aleph startup 

    csh -f $alephe_root/aleph_startup

    Additional Information

    Note: the following lines, showing evidence of the server time change, were seen in the www_server log:
    2014-10-05 16:41:41 12 [002] [vrb] server_main: OUT 0.2277 11795
    2014-10-05 12:42:02 43 [000] [vrb] IN 20141005 124202 <---- time drops back 4 hours!


    For other causes, not involving server clock change, see Article 000009299 ("License limit exceeded or System is overloaded").

     


    • Article last edited: 21-Jan-2020
    View article in the Exlibris Knowledge Center
    1. Back to top
      • "source aleph_start" hangs
      • "The IBM Cognos gateway is unable to connect to the IBM Cognos BI server" when trying to login to ARC
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Language
      English
      Product
      Aleph
    2. Tags
      1. 20
      2. contype:kba
      3. Prod:Aleph
      4. System Management (500)
      5. Type:General
    1. © Copyright 2025 Ex Libris Knowledge Center
    2. Powered by CXone Expert ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved