Not-logged-on OPAC user gets wrong base (generic "USM01" base)
- Article Type: General
- Product: Aleph
- Product Version: 20
Description:
We just upgraded to version 18. When we connect to the catalog, we are taken to the default, generic ("USM01") OPAC screen rather than our library-specific screen.
Resolution:
The default base (and there for the default screen) which a user who is not logged-in connects to in the OPAC is determined by the $usr_library z61_base value for the "ALEPH" z61 record.
{ If the user is not logged-on, the system will look for a z61 "ip profile" matching the ip address; if none, it will use the "ALEPH" profile. }
It seems that the z61_base is "USM01". It needs to be changed.
To see the current setting, try:
select Z61_REC_KEY, Z61_BASE from z61 where Z61_REC_KEY LIKE 'ALEPH%';
- Article last edited: 10/8/2013