    Why aren't changes for patron records written in z307?

     

    • Product: Aleph
    • Product Version: 20, 21, 22, 23
    • Relevant for Installation Type: Dedicated-Direct, Direct, Local, Total Care

     

    Question    
    Why aren't changes for patron records written in the xxx50.z307 (patron logger) file? 

     

    Answer    
    Check the table ./xxx50/tab/tab_patron_log.lng. The entries have to be set to 'Y' in column 2. 

    ./xxx50/tab/tab_patron_log.<lng> 

    !1  2 3 
    !!!-!-!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!-> 
    001 N Update of global patron record-Details --> Change value in column from 'N' to 'Y' 
    002 N Update of global patron record-Blocks 
    003 N Update of local patron record-Details 
    004 N Update of local patron record-Blocks 
    005 N Update of local patron record-Privileges 
    006 N Update of patron addresses 
    007 N Update of patron IDs 

    010 N Delete of global patron record 
    011 N Delete of local patron record 
    012 N Delete of patron address record 
    013 N Delete of patron ID 

    020 N New global patron record created 
    021 N New local patron record created 
    022 N New patron address record created 
    023 N New patron ID created 

    When value is set to 'Y', the z307 patron logger will be written.

     

     