    No headers
    • Product: Rosetta
    • Product Version:

     

    Problem Symptoms:
    Open an IE in the Webeditor.
    Click on Metadata.
    Click Edit or View DC.
    'Parsing Error - null' appear

     

    'Parsing Error - null'.jpg



    Cause:
    Some DC are missing from the webeditor_dublincore_configuration.xml

    Resolution:

    Go to "Administer the system" > "General" > "Configuration Files" filter the list by File Group=Metadata Editing Configuration, Sub-group=Web Editor

    Edit the webeditor_dublincore_configuration.xml and add the missing DC.

     

    For example:

    <element>
            <code>dcterms:provenance</code>
            <desc>Provenance</desc>
            <qualifiers>
                <qualifier>
                    <code>xsi:type</code>
                    <desc>Type</desc>
                    <format>LIST</format>
                    <values>
                        <value>dcterms:URI</value>
                    </values>
                </qualifier>
            </qualifiers>
            <validationRoutines>
                <validationRoutine></validationRoutine>
            </validationRoutines>
            <correctionRoutines>
                <correctionRoutine></correctionRoutine>
            </correctionRoutines>
    </element>

     

     


    • Article last edited: 14-August-2016
    View article in the Exlibris Knowledge Center
    1. Back to top
      • PDS handshake alert on SSL environment
      • How to unassign a SIP or IE that is assigned to another user
    • Was this article helpful?

    Recommended articles

    1. Article type
      Topic
      Content Type
      Knowledge Article
      Language
      English
      Product
      Rosetta
    2. Tags
      1. Prod:Rosetta
    1. © Copyright 2025 Ex Libris Knowledge Center
    2. Powered by CXone Expert ®
    • Term of Use
    • Privacy Policy
    • Contact Us
    2025 Ex Libris. All rights reserved